Kane International Ltd - Home
Home arrow Products arrow Emissions Monitoring arrow KM9106EM Quintox Emissions Analyser with Heated Line and Peltier Chiller
KM9106EM Quintox Emissions Analyser with Heated Line and Peltier Chiller Print E-mail

KM9106EM Quintox Emissions Analyser with Heated Line and Peltier Chiller.

 

km9106co_kit_no_cert_rgb

 

 

 

 

 

 

 

 

 

 

 

The KM9106EM Quintox is the latest upgrade of the KM9106 and KM9006, and it has established itself as the most cost effective and versatile portable analyser. From its most basic form as a boiler tuning analyser it provides a versatile and cost effective platform that allows enhancements up to a fully portable semi-continuous emissions monitoring system.

 

 Click below to Download

Specification

Manual

 

 

 

 

 

 

 

 KMHL3000 - 3000mm Heated Sample Hose:

 

 h_300

 

 

 

 

 

 

 

This 3 metre sample line is heated to 120°C using the latest self limiting heating elements. The internal sample tube that is in contact with the sample gas is made from a PTFE.

 

KMHP1200 - 1200mm Heated Flue Probe:

This flue probe has its own integral self limiting heater and a 1200mm insertion length.

 

KMDM220 - 220 Vac Drier Module:

This is a self contained Peltier cooled gas drier module that fits into the front compartment of a standard KM9106 carrying case. The Peltier element and its associated cooling fan are powered from a 220 Vac power supply. The cooling chamber is fitted with a peristaltic pump to automatically remove condensate.

 Features:                                                       
  • Heated combustion probe.
  • Heated 3 metre sample line.
  • Peltier Cooler.
  • Peristaltic Condensate Pump.
  • A comprehensive range of optional probes is available, allowing smoke measurement, higher temperatures and longer shafts.
  • Clear, backlight, 4 line display. Display preset pages or personally congifured individual screens.
  • Tactile keypad - simple to use.
  • Handset stores up to 1926 boiler tests.
  • Remote handset with protective rubber boot.
  • Tough case with Aluminium alloy structure and carry strap.

Standard Product KM9106EM Measures:

  • Oxygen
  • Carbon Monoxide (CO)
  • Flue Temp (Optional)
  • Ambient Temp
  • Inlet Temp (Optional)
  • Differential Pressure
  • Nitric Oxide (NO)
  • Nitrogen Dioxide (NO2)
  • Sulphur Dioxide (SO2)

Calculates:

  • Efficiency (Nett and Gross)
  • Nett Temperature
  • Date and Time
  • Excess Air
  • Lambda
  • Losses
  • CO/ CO2 Ratio
  • Poison Index
  • Oxygen Sensor Life
  • Battery Life
  • Carbon Dioxide 

 

 455_007  pict0001

 pict0008 

 pict0010 

 

Standard Features:

  • Oxygen sensor with 2 years warranty.
  • Hydrogen compensated CO sensor with internal filtering that operates to 10,000 ppm.
  • Automatic cross sensitivity compensation between toxic gas sensors.
  • Powerful extraction pump that produces 500 mBar of suction and over 1.0 litres per minute extraction, with a flue vacuum of 25 kPa.
  • Pump on/ off control via handset.
  • Tough handset with tactile keypad and internal data store.
  • Stores 1926 boiler tests within the handset.
  • Integral plain paper printer for immediate record keeping.
  • User defined printouts for customised reports.
  • Timed print and/ or data store facility for automatic record keeping.
 Optional Extras:
  • KM9106PUR - Main Purge solenoid to facilitate regular automatic fresh air purging to refresh the electrochemical sensors whilst long term monitering.

 

  • KM9106HPUR - Changeover solenoid and purge pump to allow automatic switching between low and high range sensors. This provides protection for the standard CO sensor in situations where controlled combustion has not been established eg. During boiler commissioning. The high CO sensor is rated to 10%.

 

Please Contact us for Further Information.

 
< Prev   Next >
 