Page 4 of 4
Technical Specification
|
Parameter
|
Resolution
|
Accuracy
|
Range
|
|
Temperature Measurement
|
|
Flue Temperature
|
0.1°C/F
|
±2°C (5°F) ±0.3% reading
|
0-600°C 32-1112°F
|
|
Inlet Temperature (Internal Sensor)
|
0.1°C/F |
±1°C/F ±0.3% reading
|
0-50°C 32-122°F
|
| Inlet Temperature (External Sensor) |
0.1°C/F
|
±2°C (5°F) ±0.3% reading
|
0-600°C 32-1112°F
|
|
Pressure Measurement
|
|
Also measures in mbar and other scales
|
0.1 Pa |
±0.5 Pa |
±20 Pa |
| 0.1 Pa |
±3 Pa |
±100 Pa |
| 1 Pa |
±3% of reading |
±2000 Pa |
| 0.01 hPa |
±3% of reading |
±80 hPa |
| |
|
|
| Gas Measurement |
|
Oxygen
|
0.1%
|
±0.2%*1
|
0-21%
|
| Carbon Monoxide (KANE450CO) |
1 pmm |
±10 ppm <100ppm*1
±5% of reading
|
0-2000 ppm nom 4000 ppm max for 15 minutes |
| (KANE450COH) Standard in UK |
1 pmm |
±20 ppm <400 ppm
±5% <5000 ppm
±10% >5000 ppm
|
0-10,000 ppm |
| Nitric Oxide (NO) (low range) |
1 ppm |
±2 ppm < 30 ppm*1
±5 ppm > 30 ppm
|
0-100 ppm |
| Carbon Dioxide*2 |
0.1% |
±0.3% reading |
0-30% |
| Efficiency*2 |
0.1% |
±1.0% reading |
0-99.9% |
|
Excess Air*2
|
0.1%
|
±0.2% |
0-250% |
*1 using dry gases at STP
*2 calculated
|
Pre-programmed Fuels
|
Natural gas, Light Oil, Propane, Butane, LPG.
|
|
Dimensions
Weight
Handset
Probe
|
0.77kg / 2.2lb handset with boot
200 x 45 x 90mm (7.9" x 1.8" x 3.5")
L300mm (11.8") x Dia 6mm (0.25") with 200mm (7.8") long stainless steel shaft, type K thermocouple and 3m (6’) long neoprene hose
|
|
Ambient Operating Range
|
+0°C to +40°C / 32-104°F
10% to 90% RH non- condensing
|
|
Storage Capacity LOG
REPORT
|
255 sets of test results in volatile memory
8 sets of each report in volatile memory
|
|
Battery Type / Life
|
4 AA cells
>12 hours using Alkaline AA cells
|
|
Chargers (optional)
|
220v fast charger, for NiMH batteries only
12v in vehicle charger, for NiMH batteries only
|
|