KANE455
- Easy to use rotay dial
- Long Life CO Sensor
- Compact boiler analyser with high accuracy pressure readings.
- Four line display controlled by 9 position rotary switch.
- Measures O2, CO2 & CO (0-2,000ppm)
- Differential pressure and differential temperature.
- Calculates CO/CO2 ratio, excess air and efficiency for multi-fuel, gaseous fuels and light oils (28/35 sec).
- Infra-red output to optional printer. Which could print reports for combustion, pressure, let-by/tightness, temperature and room CO build up.
- Internal memory holds:
99 Combustion tests
20 Pressure tests
20 Tightness tests
20 Temperature tests
20 Room CO tests
- Protective rubber sleeve with magnet for “hands free” use
Contents:
- Analyser with protective rubber boot
- KMCP2 flue probe
- 4 x NiMH rechargeable batteries
- Charger
|
Parameter |
Resolution |
Accuracy |
Range |
|
Temp Measurement |
1°C/F |
|
0-600°C |
|
Gas Measurement Carbon Dioxide |
0.1% 0.1% |
+0.2% *1 +0.3% reading |
0-21% |
|
Pressure (differential)
|
Maximum 0.001 mBar <25mBar
|
+0.005 mBar +0.03 mBar +3% of reading
|
+0.2 mBar +1 mBar +80 mBa |
1 Using dry gases at STP *2 Calculated
|
Pre-programmed Fuels |
Natural gas, Propane, Butane, LPG Light Oils (28/35 sec), Wood Pellets |
|
Storage Capacity |
99 Combustion tests |
|
Ambient Operating Range |
0oC to +40oC 10% to 90% RH non-condensing |
|
Chargers (optional) |
220v charger, for NiMH batteries only |
|
Dimensions |
0.8kg handset with boot |
- KMIRP Infra-red printer
- Carry Case
- NiMh Batteries and Charger
- KAL1Air/liquid probe
- KPCP Clamp on probes
- KANEMSP Smoke pump
- 0-300psi pressure gauge & pressure gauge manifold
- Compound gauge (pressure and vacuum)
- High pressure hose & 2 x adaptors
- ASP2 Appliance sampling probe kit
- Larger carry case
Customer Reviews
- Kane455 Great piece of Kit! Review by John Wilson - Technical Service Manager at Ravenheat Manufacturing Ltd
- Having had a Kane455 for over 18 months and monitoring the performance of the equipment over that period of time we are more than happy with the instrument. We feel it is essential that our Field Service Engineers use the analyser to its full potential and accurate data can be easily transported via the printer it is also possible to link to a blue tooth devicesupply or direct to our PC. We find the crocodile clip temperature sensing probes essential for checking differential temperatures accross flow and returns and it is useful for checking dhw plate heat exchangers for debris and accurate temperatures for checking NTC thermisters can be gained. We are also pleased with the cost of ownership with the longlife electronic sensors. We work very closely with all members of the sales team who understand their product and are always more than happy to help. (Posted on 15/08/2011)












2012