Tech Tips/FAQs
| How is excess air calculated? |
|
Excess Air = 100 x (20.9%) / (20.9% -O2m%) - 100% Where O2 m% = The measured value of oxygen in the exhaust.
Examples: When O2m% = 0% Then excess air = 0 When O2m% = 5% Then: excess air = 100 x (20.9%) / (20.9%-5%) - 100% excess air = 100 x (20.9%) / (15.9%) - 100% excess air = 100 x (1.31) - 100%
excess air = 31%
|












2012