How do I set the CO/CO2 Ratio to the top line on a KANE250?

  1. Power up the KANE250 Flue Gas Analyser and allow it to purge in fresh air.
  2. Rotate the dial to MENU, the screen now shows MENU SET TIME
  3. Press the PRINT key (second from the left) twice. The screen now displays MENU TOP LINE.
  4. Press the HOLD key (far right hand side). The display now shows TOP LINE and the current time.
  5. Press the PUMP key (second from the right) THREE times, the display now shows TOP LINE R 0.0000.
  6. Press the HOLD key (far right hand side). This sets the top line to the CO/CO2 Ratio. The screen will now show MENU C <-----> F.
  7. Rotate the dial to CO.